16 Engineer programming via the keypadCommunication140Vanderbilt Installation & Configuration Manual A6V1027695901.05.2016Glass Reset Used to switch on the power for the glassbreak interface module and to remove powerin order to reset the device. The output is reset if a user enters their code, the zone isnot in the closed state, and the bells deactivated.Confirmed holdup Activates in the following scenarios for PD6662 compliance: two hold-up zone activations more than two minutes apart a hold-up zone and a panic zone activation more than two minutes apart If a hold-up zone and a tamper zone or a panic zone and a tamper zone activationoccurs within the two minute periodFull Engineer Activates if an engineer is on site and the system is in full engineer mode.*This output type can only indicate system wide events (no area specific events).See also Configuring system latch and auto set outputs [➙ 202]16.11 Communication1. Scroll to COMMUNICATION and press SELECT.2. Scroll to the desired programming option.16.11.1 Serial PortsThe serial ports allow older style PCs to be connected to the system or otherperipheral equipment like printers.1. Scroll to SERIAL PORTS.2. Press SELECT.3. Scroll to the serial port to be programmed.4. Select the desired programming option shown in the table below.5. Press BACK to exit.TYPE Determines if type is TERMINAL (system information) or PRINTER (SPC event log)BAUD RATE Determines the speed of the communication between the panel and the peripheralequipment. Please note that the baud rate must be set the same as both items ofequipment.DATA BITS Determines the length of data packet to be transferred between the panel and theperipheral equipment. Please note that the data bits must be set the same for bothitems of equipment.STOP BITS Determines the number of stop bits at the end of the data packet. Please note that thestop bits must be set the same for both items of equipment.PARITY Determines the parity (odd/even) of the data packet. Please note that the parity mustbe set the same for both items of equipment.FLOWCONTROLDetermines if the data is under hardware (RTS, CTS) or software control (None).Please note that the flow control must be set the same for both items of equipment.16.11.2 Ethernet PortsTo program the Ethernet port:1. Scroll to ETHERNET PORT.