10/002-196 Phaser 790/DocuColor 2006011-702Initial IssueStatus Indicator RAPs011-702 Sorter Cover Open RAPSorter Control PWB logic has detected that the Sorter Top Cover is open.Initial ActionsSwitch off the Copier/Printer then switch on the Copier/Printer to try and clear the “Close SorterCover” Message. If the message does not clear or clears momentarily and then returns, con-tinue with this RAP.ProcedureMeasure the voltage between J 7-1 (+) of the Sorter Control PWB and GND (-). Ensure that theTop Cover is closed and then opened. The voltage is at first High (+24 VDC) and thengoes Low (0 VDC).Y NThe voltage between J7-1 of the Sorter Control PWB and GND remains High (+24VDC).Y NThere is +24 VDC between J7-2 of the Sorter Control PWB and GND.Y NThere is +24 VDC between J 8-7 of the Sorter Control PWB and GND.Y NGo to Flag 2. Check the wires for an open circuit.The fuse may be blown. Replace the fuse (PL 19.1) on the Sorter Control PWBwith a fuse of the same rating. If the problem persists, replace the Sorter Con-trol PWB (PL 19.1).Go to Flag 1. Check the wires for an open circuit. If the wiring is OK, ensure that theTop Cover physically actuates the Interlock. Replace the Top Cover (PL 19.1) asrequired.Replace the Sorter Control PWB (PL 19.1).This indicates that the Top Cover and the Top Cover Interlock are working correctly. If the prob-lem persists, replace the Sorter Control PWB (PL 19.1).