10/004-78 Phaser 790/DocuColor 2006REP 8.29Initial IssueRepairs and AdjustmentsREP 8.29 Duplex Exit SensorParts List on PL 15.3RemovalWARNINGTo avoid personal injury or shock, do not perform repair activities with the power switchon or electrical power applied to the machine.1. Switch off the machine power and disconnect the machine Power Cord.2. Remove the Duplex Tray Assembly. (REP 8.27)3. Remove the Front Cover of the Duplex Tray Assembly.4. Remove the Duplex Registration Chute. (Figure 1)Figure 1 Removing the Duplex Registration Chute5. Remove the Rail Assembly. (Figure 2)Figure 2 Removing the Rail Assembly6. Remove the Chute Support. (Figure 3)Figure 3 Removing the Chute Support1Disconnect the connector2Remove the twoscrews and theDuplex RegistrationChute1Remove the screwsand remove the RailAssembly1Remove thescrew2Press and hold therelease tab, whilemoving the ChuteSupport in thedirection indicated