10/004-123Phaser 790/DocuColor 2006 REP 10.14, REP 10.15Repairs and AdjustmentsInitial IssueREP 10.14 Exchange SolenoidParts List on PL 8.5RemovalWARNINGTo avoid personal injury or shock, do not perform repair activities with the power switchon or electrical power applied to the machine.1. Switch off the machine power and disconnect the machine Power Cord.2. Remove the Exit Tray Assembly (REP 8.30).3. Remove the Fuser Assembly (REP 10.1).4. Remove the Main Fuser Assembly (REP 10.2).5. Remove the Exchange Chute (REP 10.13).CAUTIONThe Fuser Rear Rail and Fuser Tray Assembly are connected by a harness. Be careful not topull too far apart while disassembling the components.The gear is no longer secured when the EXCHANGE BRACKET is removed. Be careful not toallow the gear to fall out while disassembling the components.6. Remove the Exchange Solenoid (Figure 1).Replacement1. Reinstall the Exchange Solenoid in the reverse order of removal.Figure 1 Removing the Exchange SolenoidREP 10.15 Cleaner Cam SolenoidParts List on PL 8.7RemovalWARNINGTo avoid personal injury or shock, do not perform repair activities with the power switchon or electrical power applied to the machine.1. Switch off the machine power and disconnect the machine Power Cord.2. Remove the Exit Tray Assembly (REP 8.30).3. Remove the Fuser Assembly (REP 10.1).4. Remove the Main Fuser Assembly (REP 10.2).CAUTIONThe Fuser Rear Rail and Fuser Tray Assembly are connected by a harness. Be careful not topull too far apart while disassembling the components.5. Remove the Cleaner Cam Solenoid (Figure 1).Figure 1 Removing the Cleaner Cam Solenoid1Remove thescrews2Remove theFuser Rear Railtogether withthe Gear Cover3Disconnect theconnector4Remove thescrews to removethe ExchangeSolenoid Assem-bly5Remove thescrews toremove theExchangeSolenoid1Remove thescrews2Remove theFuser RearRail with theGear Cover3Disconnect theconnector4Remove the screws.Then, remove the InputBracket Assembly5Remove the screws to remove theCleaner Cam Solenoid