4 Operation4.5.4 Digital Operator Displays during Testing without Motor4-324.5.4 Digital Operator Displays during Testing without MotorAn asterisk (∗) is displayed before status display to indicate the test without a motor operation is in progress.(Example: Status of power to the servomotor is OFF)Note: The test without a motor status is not displayed during alarm occurs (A.).Display Status*RUN Power is supplied to the servomotor.*BB Power to the servomotor is OFF.*PT NT Forward or reverse run is prohibited.*P-OT Forward run is prohibited.*N-OT Reverse run is prohibited.*HBB In hard-wire base block (safety) state.∗ B B − P R M / M O N −U n 0 0 0 = 0 0 0 0 0 0U n 0 0 2 = 0 0 0 0 0 0U n 0 0 8 = 0 0 0 0 0 0 0 0 0 0 0U n 0 0 D = 0 0 0 0 0 0 0 0 0 0 0