43FT-817ND Operating ManualTIME -O UT T IMERMost often used on FM, the transmitter’s Time-Out Timer (TOT) feature disables the trans-mitter after a user-defined period of transmission. This feature may be useful in preventinga “stuck microphone” (accidental closure of the PTT switch) from causing interference toother users, and it will also force you to keep your transmission short, thereby conservingbattery power.To activate the Time-Out Timer:1. Press and hold in the key for one second to enter the Menu mode.2. Rotate the knob to recall Menu #49 (TOT TIME).3. The default setting for this feature is “off.” Rotate the knob to set a new time-outsetting (from 1 minute to 20 minutes).4. When you have made your selection, press and hold in the key for one second to savethe new setting and exit to normal operation.WEATHER FAX M ONITORINGMonitoring of HF WeatherFax broadcasts is easily accomplished using the FT-817ND.1. Before proceeding, be certain that the WeatherFax demodulator is properly connected toPins 5 (DATA OUT 1200bps) and 2 (GND) of the rear panel DATA jack.2. Set the transceiver to the VFO mode, and set the operating mode to “DIG,” setting Menu#26 to PSK31-U, as described previously.3. Now, select the operating frequency of the station transmitting the WeatherFax broad-cast. Note that, in the USB mode, the frequency you should program onto the display istypically 1.90 kHz below the station’s “assigned” frequency. Thus for a WeatherFaxstation assigned to 8.682.0 MHz, tune to 8.680.1 MHz.4. When the WeatherFax broadcast begins, no further operator intervention should be neededfrom the transceiver standpoint. The audio level from the DATA jack on the rear of thetransceiver is fixed, and cannot be adjusted.Fine adjustments in the gray-scale and the frame alignment are accomplished using the com-puter and software connected to your WeatherFax demodulator.TRANSMITTER O PERATION