11.5 Traveling speed defaultsAfter entering the installation specifications and carrying out the automatic parameter assignment, thetraveling speeds "V_2" and "V_3" are pre-configured in the Travelling menu, dependent on "V*".Description Parameter pre-signmentIntermediate speed V_2 V_2 50% V*Travel speed V_3 V_3 100% V*The speeds listed in the table below are permanently preset and thus independent of "V*".Description Parameter pre-signmentPositioning speed V_1 0,05 m/sReadjustment speed V_Z 0,05 m/sAdditional speed V_4 V_4 0,32 m/sAdditional speed V_5 V_5 0,32 m/sAdditional speed V_6 V_6 0,32 m/sAdditional speed V_7 V_7 0,32 m/s11.6 Distance-dependent decelerationIn a path-dependent deceleration, the deceleration paths are always identical. Independent of thespeed reached at the start of the deceleration.The path-dependent deceleration can be activated in the menu Decelerating/S_ABH = ONPath dependent deceleration is carried out during deceleration of:• V3 R V1• V2 R V1• V3 R Drehzahl 0 (only in DCP2/DCP4 protocol)• V3 R Drehzahl 0 (only in DCP2/DCP4 protocol)During all other switchovers between two speeds, the deceleration is carried out time-dependent.InformationBefore removing the digital input for the travel speeds V_3 or V_2 the input for the travel speed V_1must be applied (see diagram "Normal stop at distance-dependent deceleration").If it is not possible to control two travelling speeds simultaneously for technical reasons (e.g. control ofthe speeds by an alternating contact), the distance-dependent delay with the Control system/SIM_-V1=ON parameter can be activated!Here it must be noted that the positioning speed V_1 must be activated 100 ms after deactivation ofthe travelling speeds V_3 or V_2 at the latest!If binary speed is specified, there is only a distance-dependent delay at Control system/SIM_V1=ON!InformationIf the signal for the higher traveling speed (e.g. V_3) is switched off for a short time, the inverterdecelerates the motor to positioning speed V_1. For safety reasons, retriggering a higher travelingspeed is ignored. Triggering at a higher traveling speeds is only possible after all the inputs for thetraveling speed have been switched off and the motor has reached the speed 0.Original operating instructionsZETADYN 3C Travel optionsR-TBA08_03-GB 1619 Part.-No. 00163322-GB111/204