13.6 Operating conditions of the inverterThe frequency inverter software divides the operating curve into various sections. Each ofthese sections is assigned a status number that refers to a defined service condition.If an error occurs, the status number is stored with the error number in ther error list.Furthermore, the operating conditions are displayed with the status number and in plain test in theInfo/Page02 menu.status Condition of the inverter status Condition of the inverter10 Checking of voltage supply 430 Constant running at speed V3(time-dependent,V1 is not activated)21 Check software version 431 Round down the acceleration to V3 (distance-de-pendent)22 Parameter transmission 432 Linear acceleration to V3 (distance-dependent)30 Check absolute value encoder 433 Constant travel with V3 (distance-dependent)4142Check input BC41: Power feedback unit42: Brake chopper or brake resistor435 Deceleration with safety ramp50 Adjust current transformer 440 distance dependent travel with DCP470 Check temperature power unit 480 Retract to standstill100 Device off 490 fast stop105 Power feedback unit on standby 500 Keep motor at speed 0 (T4)110 Machine ready 510 Wait until motor brakes are closed (T5)200 Start-up check 515 Brake gets additional current feed for 1s210 ... 223 Check absolute value encoder 520 Switch off current to motor (T5b)300 Wait until motor contactors switched on (T0) 530 Wait until motor contactors switched off (T6)305 Checking the motor phases 535 Travel interrupted due to interruption of the con-troller enable RF310311 Build-up of magnetic field in the motor (T1) 536 Travel interrupted due to interruption of the con-tactor monitor COx320 Wait until motor brakes have opened (T2) 540 Wait for standstill330 Accelerate motor to speed V_T3 (T3) 550 Checking the input BR after travel finished340 Start up 560 End of travel400 Accelerate to speed Vx 900 Delay of automatic acknowledgement after reme-dying the cause of the fault (2 s)402 Constant running at speed Vx 950 Parameter change404 Delay from speed Vx 982 Motor type changed410 Constant running at speed V1 988 Wait for reset420 Constant running at speed V2 990 Fault input BC421 Round down the acceleration to V2 (distance-de-pendent) 991 No absolute value encoder detected422 Linear acceleration to V2 (distance-dependent) 992 Temperature of the power section missing423 Constant travel with V2 (distance-dependent) 997 Frequency converter is in stand-by mode424 Rounding up and linear delay from V2 (distance-dependent) 998 Wait until frequency converter is switched off425 Rounding down of the delay from V2 (distance-dependent)4xx2xx 5xx3xxTravel curve with related status numbersOriginal operating instructionsZETADYN 3C Error diagnosisR-TBA08_03-GB 1619 Part.-No. 00163322-GB149/204