InformationThe paramters which are necessary for the Open-Loop-operation are only displayd with the paramterC_MOD=U/f. The parameters are described in the chapter Open-Loop-operation".10.14 Parameter set 2 menuA second set of parameters can be stored in the inverter. This can be used for:• Emergency evacuation• Normal travel with changed parameter values• Parameter back-upParameter Description Value range Factory set-tingF_PAR2 Function allocation of parameter set 2Locked: 2.nd parameter set is blocked2.ndParameter set: Activates the 2.nd parameter setEVAC 3: Emergency evacuation with evacuation module EVAC3EVA. 3*AC: Emergency evacuation through three-phase currentemergency-generatorEVA. 1*AC: Emergency evacuation through UPSUPS: Emergency evacuation through UPS (with decreasedpower)Locked2nd parameter setEVAC 3EVA. 3*ACEVA. 1*ACUPSLockedU_ACCU Accu nominal voltageConfiguring the rated voltage of the rechargeable battery duringevacuation with evacuation unit EVAC 3 ("f_PARA2=EVAC 3B",see "Emergency evacuation" chapter)60 ... 565 V 120P_UPS Max. Load UPSConfiguring the available power of the UPS during evacuationwith UPS ("f_PARA2=UPS", see "Emergency evacuation" chap-ter)0.0 ... 70.0 kW 1.0RS_UPS Stator resistorEnter the resistor of the stator of themotor with "f_PARA2=UPS" 0.0 ... 9.99 Ohm 1.00STOP Stop function to improve the positioning accuracy in the evacua-tion mode "f_PARA2=UPS"ON:- Brake is closed when the switch point for V_1 is closed.- Brake is closed when the residual path configured in S_STOPhas been reached (only for DCP02/04Off: Stop function deactivatedOnOff OffCopy Copy parameter setOFF: Function deactivatedPARA1->2: copies the data from 1st parameter set into the 2ndparameter setOffPara 1->2 OffOriginal operating instructionsZETADYN 3C Parameter listR-TBA08_03-GB 1619 Part.-No. 00163322-GB91/204