Error no. Error text Error cause M S590 RV1/RV2:Change Fault: Change the direction specification during active travelAdditional information: Display of the set direction1 = RV13 = RV2Remedy: Check control of travel directions● ●13.5.9 Error 7xx• Trip abort due to errors between frequency inverter and control systemError no. Error text Error cause M S710 DCP: Timeout Error: DCP communication interrupted during travelRemedy: check wiring (shields)● ●715 DCP: G0-G7 fail ! Error: Transmission error in the DCP protocol: Telegram for the speed preset(G0-G7) not receivedRemedy: Possibly the DCP-function of the elevator control is not compatible● ●720 DCP: Delay fail Error: The DCP residual path increases during deceleration by more than 5cmRemedy: Check the absolute rotary encoder for its residual path determinationWrong residual path signal from open loop control● ●721 DCP: Dist. fail Fault: There is no change in the residual path for 200 ms during the runRemedy: Check the absolute rotary encoder for its residual path determinationWrong residual path signal from open loop control● ●722 DCP: s_rest = 0? Error: Residual path > 20mm jumps to 0mmRemedy: Check the absolute rotary encoder for its residual path determinationWrong residual path signal from open loop control● ●723 DCP: s_rest < 0! Error: A negative residual path is transmitted during travelRemedy: Check the DCP wiring● ●780 DCP: Quick Start >20s Error: In the quick start function, input "V=0" is triggered for over 20sRemedy: Shorten the time in which "V=0" is triggered● ●781 v0 at travel ?!l Error: Input "V=0" is triggered during travelRemedy: Check the triggering of "V=0"● ●799 RF:Failure Error: Control enable RF was switched off during travel (error evaluation only iferror no. 799 is entered in the error mask)Remedy: Check the triggering of "RF"● ●13.5.10 Error 8xx• Errors which can occur in operation with CANopen LiftIf an error occurs during operation with CANopen, the frequency inverter runs through status "ST_De-lay" and finally goes to status "Wait drivecom. off". At this status the frequency inverter waits until thecontrol system sends the command "Fault Reset".Error no. Error text Error cause M S800 CAN: Timeout Errors in Velocity Mode:Heartbeat from control system is missing or at wrong time.Errors in Position Mode:Heartbeat from control system and/or encoder is missing or at wrong time.Adjustment:Check CAN-connectionCheck if devices have the right heartbeat.●810 CAN: Quick Stop Det. Error:Control system activates a quick stop.820 CAN: Illegal Status Error:Control system sends commands in wrong order.Adjustment:Take care to the right order in CAN drive cycle●Original operating instructionsZETADYN 3C Error diagnosisR-TBA08_03-GB 1619 Part.-No. 00163322-GB145/204