13.5.4 Error 1xx• Hardware configuration error• Software errorError no. Error text Error cause M S100 Serial no. missing Inverter / CU does not have a serial number, e.g. after a component replace-ment●101 System-Error An internal, defective component was found during a self-test of the inverter ●110120 CU: No ID CU ID no. was not detected:CU is not present or its ID EEPROM does not reply●111 CUSH: No ID Shunt ID no. was not detected:Shunt module is not present or its ID EEPROM does not reply●113123 CUEE: No ID ID No. of the extension card for the encoder is not recognized: extensionmodule is not present or its ID EEPROM does not reply●115125 SP: No ID Switching power supply ID no. was not detected: Switching power supply is notpresent or its ID EEPROM does not reply●116126 PP: No ID Power print ID no. was not detected:Power print is not present or its ID EEPROM does not reply●117127 MP: No ID The print module ID no. was not detected:Module Print is not present or its ID EEPROM does not reply●121 CUSH: ID-Error Internal shunt module was detected but there are problems with the shuntmodule's informational content●140 MP:Unknown IGBT A unknown IGBT-module was recognized141 MP: Temp.Sens? The external temperature sensor for the Modul Print is not recognized ●150 HW-Conflict ! Shuntmodul, Power Print and Modul Prind do not match155 No Analog-Input! Frequency converter type ZETADYN 3-HY is not equipped with an analogueinput (X-AN)●174 CUMT:Not detectOption module for the temperature monitoring of the motor is nit recognized:Check the configuration for rhe temperature monitoring in the "Monitoring"menu●180 UF CTRL=DCP2/4Error: DCP2 or DCP4 is entered for the communication between inverter andelevator contol. This is not possible with Open-Loop-operationRemedy: Enter DCP1 or DCP3 for the communication●13.5.5 Error 2xx• Configuration errorError no. Error text Error cause M S200 Stop inputError: A parameter is open while apply a correct travel command (RF + RVx +Vx)Remedy: End parameter inputs●201 Motor name plate Error: a parameter in the "Motor name plate" menu has not been assignedRemedy: Check the parameter in the "Motor name plate" menu,202 MOT_TYP = ? Error: No motor type was selected in the "Motor name plate" menuRemedy: Enter in the "Motor name plate"menu●203 n* = 0?Error: No speed was entered in the "Installation" menuRemedy: Enter the speed at V* in the "Installation" menu directly or have itcalculated based on the installation data●204 n* > 3*n Error: n* was incorrectly calculated due to incorrect installation data (n* >3xn)Remedy: Check the installation data for correct entry●205 Input duplicated Error: two digital inputs are assigned with the same functionRemedy: Change the function allocation of the digital inputs●Original operating instructionsZETADYN 3C Error diagnosisR-TBA08_03-GB 1619 Part.-No. 00163322-GB136/204