11.15 Fast-startThe motor is energized as the cabin door closes and the mechanical brake is opened. Motor speed iscontrolled to 0. This makes it possible to start travel immediately the door is closed.InformationThe Quickstart function may only be used in the door zone range in elevators with adjustment control.The regulations of DIN EN 81-1 must be observed.11.15.1 ModulationConfigure digital input in the Control system menu to v=0.Control|-" f_I08 v=0|-" v=0Function I08Standard DCP1Cabin door closingActuation of inputs:• RF - Controller enable• RVx - Default for travel direction• v=0 - Hold speed 0Activation of output:• RB - Controller readyMotor contacts must be switched without a delay.Motor energizedCabin door closingSetting the bits by lift control:• G2 - RPM 0• B1 – travel command• B2 – off switch• B3 – travelling speed• B4 – travel directionSetting the bits by frequency converter:• S1 – travel activeMotor contacts must be switched without a delay.Motor energized2Activation of output:• MB – mechanical brakeMotor brake must be opened without a delay.Motor speed is controlled to 0.Setting the bits by frequency converter:• S6 - mechanical brakeMotor brake must be opened without a delay.Motor speed is controlled to 0.3Cabin door is closedDeactivation of input:• v=0 - Hold speed 0Actuation of inputs:• V1 - Positioning speed or• V2 - Intermediate speed or• V3 - travel speedTravel speeds must be actuated no more than 150 msafter input "v=0" has been deactivated!Cabin door is closedSetting the bits by lift control:• G6 - Intermediate speed or• G7 – fast speed• B3 – travelling speedCancelling the bits by lift control:• G2 - RPM 0Travel speeds must be actuated no more than 150 ms after input"v=0" has been deactivated!Caution!Danger from traveling with cabin door open!In order to prevent premature starting up in the event of a defective input or fractured wire forthe "Hold speed 0" function, the signals for travel speeds should only be applied after the"Hold speed 0" function has been switched off!Original operating instructionsZETADYN 3C Travel optionsR-TBA08_03-GB 1619 Part.-No. 00163322-GB122/204