Notifier AFP-200 manuals
AFP-200
Table of contents
- installation precautions
- Technical Manuals Online! - http://www.tech-man.com
- Table Of Contents
- Table Of Contents
- Table Of Contents
- About This Manual
- Section 1 System Overview
- Components
- Panel Sounder
- Main Assemblies
- Cabinet
- Digital Communicator
- Field Charger/Power Supply - FCPS-24
- Trim Ring
- Addressable Modules
- End-of-Line Devices
- Annunciator Control System (ACS)
- EIA-232 Peripheral Devices (TB4)
- Specifications
- Relays (TB3)
- Semi-flush Mount
- Section 2 Installation
- Installation Checklist
- Backbox Mounting
- AC and DC Power Connections
- Battery Power Connection (J3)
- DC Output Power Connections (TB1)
- Standard Relays (TB3)
- Overview
- Keltron Printer
- CRT Connections
- Wiring a Signaling Line Circuit (SLC)
- SLC Devices
- SLC Performance
- Setting an SLC Address for a Module
- Wire Requirements for a Two-wire SLC
- Wire Requirements for a Four-wire SLC
- Wiring an Isolator Module (ISO-X)
- Wiring an IDC with Monitor Modules
- Wiring a Notification Appliance Circuit (NAC) or Control Circuit
- SLC Wiring with Control Modules
- SLC Wiring with an Intelligent Detector
- SLC Wiring with an NBG-12LX Addressable Manual Pull Station
- Option Module Installation
- Installing a 4XTM Module
- Installing an RTM-8 Module
- Section 3 Programming
- Getting Started
- How to Use the Programming Keypad
- Programming Shortcuts
- How to Avoid Programming Errors
- Program Change Options
- How to Enter Program Change
- Program Change Map
- Status Change Options
- Entering Status Change
- Status Change Programming Map
- Section 4 Operation
- The Membrane Panel
- How to Use the Enter Key and Cursor Keys
- How to Read System Status LED Indicators
- How to Operate the Control Panel
- How to Operate the Panel in Normal Operation
- How to Operate a Panel with a Trouble Monitor Point
- How to Operate a Panel with a Supervisory Condition
- How to Operate a Panel with a Non-Alarm Condition
- How the Control Panel Indicates a Panel Circuit Trouble
- Releasing Functions
- Intelligent Detector Functions
- Time Functions
- Coding Operation (NAC only)
- Special System Timers
- How to Enter Read Status
- Using the History Buffer
- Appendix A Power Supply Calculations
- A.3 The Main Power Supply
- A.4 Calculating the System Current Draw
- A.5 Calculating the Battery Size
- A.6 Selecting and Locating Batteries
- Appendix B NFPA Applications
- B.2 Central Station Fire Alarm Systems (Protected Premises)
- Installing a UDACT
- B.3 NFPA 72 Auxiliary Fire Alarm System
- B.4 Wiring a Remote Station Fire Alarm System
- Using a 4XTM Module
- Using an RTM-8 Module
- Appendix C Annunciators
- C.3 ACS Annunciation Interface (TB5 on CPU)
- C.5 Terminal Mode EIA-485 Connections (TB5)
- C.6 LCD-80 ACS Mode EIA-485 Connections
- C.7 Power Connections for LCD and ACS Series Annunciators
- C.8 ACS and LDM Series EIA-485 Connections
- Appendix D Releasing Applications
- Releasing Zone Functions
- Soak Timer (NFPA 16 Applications Only)
- Abort Timer
- Release Ckt
- Auxiliary Control Relay Functions
- Connecting a Releasing Device to a Control Panel through an SLC Control or Relay Module
- Appendix E Combination Fire/Burglary Applications
- Wiring for Proprietary Security Alarm Applications
- Connecting to an AM2020/AFP1010 Receiving Unit
- E.4 Operation
- Appendix F Wire Requirements
- G.1 Overview
- Action Level Pre-Alarm Function
- Selecting Pre-Alarm Application Levels
- Self-Optimizing Pre-Alarm Function
- Appendix H Special Zones
- H.3 Time Control
- Appendix I Terminal Interface Protocol
- Local Monitor Mode (LocM)
- I.3 Using the CRT-2 for Read Status
- Read Point
- View the History Buffer
- Accessing Alter Status Options
- Change Detector Sensitivity Levels
- Set the Pre-Alarm for Alert or Action Level
- Appendix J Expansion Power Supplies
- J.2 Programming
- APS-6R Calculations
- Installing the APS-6R
- Appendix K UL Power-limited Wiring Requirements
- Appendix M CBE Programming
- CBE Example 2
- Appendix N External Battery Charger
- Mounting the Charger into a Battery Box
- N.4 Connecting the CHG-120
- limited warranty