3Com Router 3000 Ethernet FamilyConfiguration Guide Chapter 11 Terminal Services3Com Corporation11-4210.110.164.4410.110.164.45SCO UNIX WorkstationRouterPCEthernetFigure 11-14 auto-execute command configuration diagramConfiguration procedure is as follows:# Configure the async interface (e.g. serial1/0/0) to work in dumb terminal mode, seethe configuration in the preceding section.# Configure the auto-execute command command.In user interface view, enter:[3Com-ui-vty0] auto-execute command telnet 10.110.164.45After configuration, press two carriage enters on the terminal connected with the asyncinterface of the router to log in to the destination host. If you want to log in again afterexiting, re-press two carriage enters.Note:To cancel the auto-execute command function, execute the undo auto-executecommand command in the relevant user interface view.11.8.5 Timely Disconnecting Dumb TerminalsPerform the following configuration in user interface view.Table 11-45 Timely disconnect the dumb terminalOperation CommandEnable timely disconnecting dumbterminal connection idle-timeout minutes [ seconds ]Restore its default value undo idle-timeout