Characters appear on the screen but they are not legible.Steps to Take:1. Make sure that the attached console is an ASCII terminal.2. Check the terminal parameters, especially the baud-rate, parity, and data bits. Thedefault parameters are: 9600 bauds, 8 data bits, 1 stop bit, no parity. If thesevalues do not work, try different settings until you find the right configuration.3. Replace the ASCII terminal.You cannot enter commands reserved for the ATM network administrator, or theSET commands do not work.Steps to Take:1. Make sure that you are logged on as the administrator.After you enter the first part of a 6416SW command and press the space bar, therest of the command is not automatically filled in.Steps to Take:1. Enter more letters in the command in order to distinguish it from other commandsthat are written similarly. Then press the space bar again.Random characters are lost.Steps to Take:1. Set the flow control on the console to XON/XOFF.Some characters are lost when you are connected to the 6416SW module througha modem.Steps to Take:1. Make sure that the STOP_BITS parameter on the console is set to 1.7-12 ONcore ATM Switch/Control Module: Installation and User's Guide