Setting Up a Configuration Console in Normal(ASCII) ModeThe following procedure sets up the configuration console in Normal mode and logs youon as the system administrator with full access to all 6416SW commands:1. Connect an ASCII-type terminal to the RS-232 console port on the front panel of the6416SW.2. In the terminal’s user guide, locate the procedure for setting parameters for baudrate, data bits, parity, and stop bits.3. Configure these configuration console settings to the values used by the 6416SWso that the configuration console and the 6416SW can communicate. Thefactory-set default settings for the 6416SW are as follows:Baud rate 9600Data bits 8Parity NoneStop bits 14. Press Enter. The following message is displayed:@ATM Switch/Control Module(c) Copyright IBM Corp. 1994, 1996. All rights reserved.Password:5. As no factory password is provided for administration first Logon, press Enter.@Welcome to system administrator service on ONcore.ONcoreATM>You can now proceed to configure the 6416SW, as described in Chapter 5,“Configuring the ATM Switch/Control Module” on page 5-1.4-7