Reconfiguring 6416SW Configuration ConsoleSettingsCarry out the procedures in this section only if you need to connect anotherdevice (besides the 6416SW configuration console) to the 6416SW, and if theother device runs at a slower baud rate, uses a different parity, or has a differentdata bit value than the 6416SW's pre-configured factory settings.For example, if you want to connect a 4800 baud modem to the 6416SW to remotelymanage the hub, you must change the factory-set default baud rate from 9600 to 4800.To do so, you would enter the following command:@ONcoreATM> set terminal baud 48 [ENTER]See theONcore Switching Hub/CELLplex 4000 ATM Command Reference Guide forinformation on the SET TERMINAL commands that allow you to reconfigureconfiguration console settings.Saving Reconfigured Configuration Console SettingsAfter you use the SET TERMINAL command to reset the baud rate, the parity, or thedata bit value for the 6416SW, the change is activated immediately and you losecommunication with the configuration console. The new configuration console setting isnot, however, permanently saved.In order to save the configuration console parameters that you reconfigure with the SETcommand, you must connect the new configuration console to the 6416SW, log on, andenter the SAVE TERMINAL command. Once saved in this way, the new configurationconsole settings remain stored in memory after you log off and in case of a powerfailure.For more information on how to reconfigure and save configuration console settings,see the sections describing the SET TERMINAL commands in theONcore SwitchingHub/CELLplex 4000 ATM Command Reference Guide.4-15