1-9Item DescriptionInterval Set the sampling interval.SampleItem Sample TypeSet the sampling type, including:z Absolute: Absolute sampling, namely, to obtain the value of thevariable when the sampling time is reached.z Delta: Delta sampling, namely, to obtain the variation value of thevariable during the sampling interval when the sampling time isreached.Owner Set the owner of the alarm entry.CreateDefault EventSelect whether to create a default event.The description of the default event is default event, the action islog-and-trap, and the owner is default owner.If there is no event, you can select to create the default event. And whenthe value of the alarm variable is higher than the alarm rising threshold orlower than the alarm falling threshold, the system will adopt the defaultaction, that is, log-and-trap.RisingThreshold Set the alarm rising threshold.Rising EventSet the action that the system will take when the value of the alarmvariable is higher than the alarm rising threshold.If the Create Default Event check box is selected, this option is notconfigurable.FallingThreshold Set the alarm falling threshold.AlarmFalling EventSet the action that the system will take when the value of the alarmvariable is lower than the alarm falling threshold.If the Create Default Event check box is selected, this option is notconfigurable.Return to RMON alarm configuration task list.Displaying RMON Statistics InformationSelect Device > RMON from the navigation tree to enter the page of the Statistics tab, as shown inFigure 1-1. Click the icon of a statistics entry to enter the page as shown in Figure 1-9, whichdisplays all statistics items on the current interface.