When the function picks up, the PICKUP output is set to TRUE.• Dimensions are provided both in inches and mm. If it is not specificallymentioned, the dimension is in mm.1.4.3 Functions, codes and symbolsAll available functions are listed in the table. All of them may not be applicable to aspecific configuration.Table 1:Functions included in the IEDFunction IEC 61850 IEC 60617 REF615RProtectionThree-phase non-directional overcurrent protection, low stage, instance 1 PHLPTOC1 3I> (1) 51P-1Three-phase non-directional overcurrent protection, high stage, instance 1 PHHPTOC1 3I>> (1) 50P-1Three-phase non-directional overcurrent protection, high stage, instance 2 PHHPTOC2 3I>> (2) 50P-2Three-phase non-directional overcurrent protection, instantaneous stage,instance 1 PHIPTOC1 3I>>> (1) 50P-3Three-phase non-directional long time overcurrent protection, low stage,instance 1 PHLTPTOC1 3I> (3) 51LTThree-phase directional overcurrent protection, low stage, instance 1 DPHLPDOC1 3I> -> (1) 67/51PThree-phase directional overcurrent protection, high stage, instance 1 DPHHPDOC1 3I>> -> (1) 67/50P-1Three-phase directional overcurrent protection, high stage, instance 2 DPHHPDOC2 3I>> -> (2) 67/50P-2Non-directional earth-fault protection, low stage, instance 1 EFLPTOC1 Io> (1) 51GNon-directional earth-fault protection, low stage, instance 2 EFLPTOC2 Io> (2) 51N-1Non-directional earth-fault protection, low stage, instance 4 EFLPTOC4 Io> (4) 50SEFNon-directional earth-fault protection, high stage, instance 1 EFHPTOC1 Io>> (1) 50G-1Non-directional earth-fault protection, high stage, instance 2 EFHPTOC2 Io>> (2) 50G-2Non-directional earth-fault protection, high stage, instance 3 EFHPTOC3 Io>> (3) 50N-1Non-directional earth-fault protection, high stage, instance 4 EFHPTOC4 Io>> (4) 50N-2Non-directional earth-fault protection, instantaneous stage, instance 1 EFIPTOC1 Io>>> (1) 50G-3Non-directional earth-fault protection, instantaneous stage, instance 2 EFIPTOC2 Io>>> (2) 50N-3Directional earth-fault protection, low stage, instance 1 DEFLPDEF1 Io> -> (1) 67/51NDirectional earth-fault protection, high stage, instance 1 DEFHPDEF1 Io>> -> (1) 67/50N-1Directional earth-fault protection, high stage, instance 2 DEFHPDEF2 Io>> -> (2) 67/50N-2Three phase directional power protection, instance 1 DPSRDIR1 I1-> (1) 32P-1Ground directional power protection, instance 1 DNZSRDIR1 I2 ->, Io-> (1) 32N-1Negative-sequence overcurrent protection, instance 1 NSPTOC1 I2> (1) 46-1Negative-sequence overcurrent protection, instance 2 NSPTOC2 I2> (2) 46-2Phase discontinuity protection PDNSPTOC1 I2/I1> 46PDTable continues on next pageSection 1 1MRS240044-IB AIntroduction8 REF615REngineering Manual