Broadcast Suppression Screen2E48-27R/2E49-27R User’s Guide5-65The following explains each field of the Broadcast Suppression screen:PORT # (Read-only)Identifies the number of the port.Total RX (Read-Only)Displays the total number of broadcast frames received.Peak Rate (Read-Only)Displays the highest number of broadcast frames received in a one secondinterval.Time Since Peak (Read-Only)Displays the time since peak rate was achieved.Threshold (Modifiable)Allows the user to set the desired limit of receive broadcast frames thatwill be forwarded per port per second.Reset Peak (Toggle)Allows the user to reset the Peak Rate. Resetting the Peak Rate also resetsthe Time Since Peak field. The Reset Peak field toggles between YES andNO. For details, refer to Section 5.18.1.[1-12] or [13-24] (Navigation Key)When the Broadcast Suppression screen displays, the current statistics aredisplayed for the first 12 ports. This field allows the user to step to asecond screen for the same type of information for ports 13 through 24.While on the second screen, the user can navigate back to the first screenby highlighting the [1-12] field and pressing ENTER. The user canchange the Threshold or Reset Peak fields while in either the first orsecond screen. For details, refer to Section 5.18.2.5.18.1 Setting the ThresholdTo set the Threshold, proceed as follows:1. Use the arrow keys to highlight the Threshold field for the selectedport.2. Type in the numbers for the desired limit. Only enter values inincrements of ten (for example; 10, 20, 30, etc.).