1. Open the following service mode, and confirm that the URL for accessing UGW is set correctly. If the correct URLis not set, set it.• SERVICE MODE > NETWORK GR.> E-RDS > RGW-ADDRESSE-RDSE-RDS SWITCHRGW-ADDRESSRGW-PORTCOM-TESTRGW-ADDRESShttps://a01.ugwdevice.net/ufix : OK keyEntry Mode: a2. Open the following service mode, and confirm the port number used when communicating with the UGW server. Ifthe correct number is not set, set it.• SERVICE MODE > NETWORK GR.> E-RDS > RGW-PORTE-RDSE-RDS SWITCHRGW-ADDRESSRGW-PORTCOM-TESTRGW-PORT443(1~65535)3. Open the following service mode, and set whether to reduce transmission costs for E-RDS data when the power isturned ON.• SERVICE MODE > NETWORK GR.> E-RDS > REDUCE SEND NETHOD4. Execute the following service mode to perform a communication test with the UGW server.• SERVICE MODE > NETWORK GR.> E-RDS > COM-TESTE-RDSE-RDS SWITCHRGW-ADDRESSEGW-PORTCOM-TESTExecute?NoYesMaintenance■ Initializing E-RDS settingsIt is possible to clear the FLASH data of E-RDS and change the E-RDS setting back to the default value.● Initialization procedure1. Press [OK] to execute the following service mode to initialize the E-RDS settings.• NETWORK GR. > E-RDS > CLEARE-RDSRGW-PORTCOM-TESTCOM-LOGCLEARExecute?NoYes● Setting values and data to be initializedThe following E-RDS settings, internal data, and Alarm filtering information are initialized.• SERVICE MODE > NETWORK GR. > E-RDS > E-RDS SWITCH• SERVICE MODE > NETWORK GR. > E-RDS > RGW-PORT• SERVICE MODE > NETWORK GR. > E-RDS > RGW-ADR• SERVICE MODE > NETWORK GR. > E-RDS > COM-LOG3. Technical Explanation (System)91