Model 190 Installation, Technical and Operation8400-M022-O1 Rev J Page 938.2 Preset Weight ComparatorsThe Model 190 indicator has three (3) outputs, which can be configuredduring setup to perform as Preset Weight Comparators “PWC”. Theoutput state of each PWC (before reaching the preset weight) is definedin section 4.4 SETUP, the d out= (Digital Output) parameter.With the PWC feature selected, during operation the indicator willcompare each enabled preset weight value with the displayed weight andthen output a signal for each preset based on the comparison results.8.2.1 Entering Preset Weight Comparators Values1. To enter the Preset Weight Comparators values, simultaneouslypress the Fn/ key and the PRINT key.2. The display will change to show Prt= (the prompt for Print TicketFormat selection). Refer to section 8.1 for details on selecting aPrint Ticket Format.3. Press the TARE key again to skip the Print Ticket Formatselection.4. The display will change to show PSEt1=.5. Press the TARE key to display the current value of the firstpreset weight value.6. If the setting displayed is acceptable, press the TARE key againto save it.7. Otherwise, use the Fn/ and UNITS/ keys to enter a new valuefor the preset weight.8. When the desired value is displayed, press the TARE key tosave it.9. Continue with this procedure until a value for each preset to be usedhas been entered.10. After the last preset value has been entered and the TARE keypressed, the indicator will return to the weight display.