Model 190 Installation, Technical and Operation8400-M022-O1 Rev J Page 514.7 Set Gravity ConstantThe Cardinal 190 Weight Indicator is equipped with an acceleration of gravityfunction which means that it can be calibrated in one location and then adjustedto match the acceleration of gravity at the location where it will used.SEtgCWith sEtgC displayed, press the TARE key. The display will change toCaLgC=. Proceed to the CaLgC= parameter.SEtgC?With sETgC? displayed, press the TARE key. The display willchange to no. Press the Fn/ key to toggle to yes and then press theTARE key. The display will change to CaLgC=. Proceed to theCaLgC= parameter. Otherwise, to skip the Set Gravity Constant setup,press the TARE key to advance to the Sio?. prompt.CALgC= (Calibrated Gravity Constant)This is the acceleration of gravity value of the location where the scalewas calibrated. Set to 0 if calibrated at location of operation or if gravityconstants are not going to be used.Press the TARE key to show the current setting. If the valuedisplayed is acceptable, press the TARE key to save it. Otherwise,use the Fn/ and UNITS/ keys to enter a new value and press theTARE key to save itoPgC= (Operating Gravity Constant)This is the acceleration of gravity value for the location where the scalewill be operated.Press the TARE key to show the current setting. If the valuedisplayed is acceptable, press the TARE key to save it. Otherwise,use the Fn/ and UNITS/ keys to enter a new value and press theTARE key to save it. Consult the factory Tech Support for theAcceleration of Gravity value for your location.