Model 190 Installation, Technical and Operation8400-M022-O1 Rev J Page 234.4 SettingsIMPORTANT! Calibration and configuration parameters are notstored in the non-volatile memory until setup is left. If power islost while in setup mode, any changes made will be lost and theindicator will revert to the previous configuration.SETUPUSA= (Domestic or International)With SEtUP displayed, press the TARE key. The display will changeto USA=. Press the TARE key to show the current setting. If thesetting displayed is acceptable, press the TARE key again to save it.Otherwise, use the Fn/ key to toggle to a new setting and then pressthe TARE key to save it.Yes (Domestic) no (International)trL= (4% Zero Range) = no trL=(4% Zero Range) = yesCAP (Capacity) = + 4% to OC CAP (Capacity) = + 9 grads to OCDate Format = MM/DD/YY Date Format = DD/MM/YYLFt= (Legal For Trade)Press the TARE key to show the current setting. If the settingdisplayed is acceptable, press the TARE key again to save it.Otherwise, use the Fn/ key to toggle to a new setting and then pressthe TARE key to save it.Yes = Interval Settings (Int=)allowed are: 1, 2, 5, 10, 20, 50no = Interval Setting (Int=) isselectable from 1 to 99.When both LFt=yes and USA=yes, the followings results occur:Scale must have between 100 and 10,000 divisionsInhibit serial data during inputtrA= (Zero Tracking Range) = 0.5 or 0 to 3trL= (4% Zero Range) = noCAP (Capacity) = + 4% to OCWhen LFt=yes and USA=no, the followings results occur:UnS= (Motion Range) = 1trL= (4% Zero Range) = yesCAP (Capacity) = + 9 grads to OC