Model 190 Installation, Technical and Operation8400-M022-O1 Rev J Page 214.3 Accessing Setup4.3.1. With the 190 ON, press the Fn/ and UNITS/ key simultaneously4.3.2. Hold both keys until the display changes to SetUP.4.3.3. Release the keys to begin setup.4.3.4. Press the UNITS/ key to step to the beginning point of each setupsection.SEtUP See NoteBelow Setup Mode (starts at USA= prompt)A-d A-d? Analog to Digital Filtering (starts at dFLt= prompt)CAL CAL? Calibration (starts at CAL1= prompt)SetgC SetgC? Set Gravity Constant (starts at CALgC= prompt)Sio Sio? Serial Input/Output (starts at bAUd= prompt)Print Print? Print Tab Settings (starts at Port= prompt)F SPAn FSPAn? Fine Span AdjustmentHi rES HirES? Display High Resolution WeightLoCoUt LCoUt? Key Lockout Feature Setupoption Opt? Configuration for Indicator Option BoardsfUnC fUnC? Function SetupCoLors CoLor? Display Colors Setup4.3.5 If you press the TARE key at the SetUP prompt, you mayproceed through to the next section (up to and including Colors)by pressing the TARE key.4.3.6 To exit setup, press the Fn/ key with any of the menu selectionsdisplayed.NOTE: With the exception of the SEtUP prompt, the promptsdisplayed for each section are different if you push the UNITS/ keyto step through the prompts instead of pressing the TARE key toproceed through the section. For example, if you press the UNITS/key with the SEtUP displayed, the next prompt displayed will be A-d.If you step through the setup prompts by pressing the TARE key,the next prompt displayed will be A-d?. In addition, at a prompt withthe ? displayed, you must press the TARE key again to proceedwith that section. To skip the section and advance you to the nextmenu selection, press the TARE key twice.