Model 190 Installation, Technical and Operation8400-M022-O1 Rev J Page 11. SPECIFICATIONSPower Requirements: 100 to 240 VAC (50/60 Hz) at 0.4A Max.Enclosure Type: Thermoplastic IP69K wall or desk-mountEnclosure Size: 9.4” W x 6.4” H x 3.7" D(239mm W x 163mm H x 93mm D)Operating Environment: Temperature: 14 to 104 ºF (-10 to +40 ºC)Humidity: 90% non-condensing (maximum)Display: Six digit, seven segment, 1.0" high Backlit LCDTransducer Excitation: 5.15 VDCSignal Input Range: 0.5 mV min. to 40 mV max. (with dead load boost)Number of Load Cells: 6 each, 350 OHM minimum resistanceLoad Cell Cable Length: 1500 feet maximum.30 feet maximum without sense linesConsult factory for other requirementsDivision Value: 1, 2, or 5 x 10, 1, 0.1, 0.01, 0.001 commercial0 to 99, non-commercialSensitivity:NON-COMMERCIALNTEPCANADA0.15 uV/e0.5uV/e (Class III/IIIL)0.5uV/e (Class III/IIIHD)Scale Divisions:NON-COMMERCIALNTEPCANADA100 to 240,000100 to 10,000 (Class III/IIIL)100 to 10,000 (Class III/IIIHD)Internal Resolution: 1 part in 16,777,216Tare Capacity: Scale CapacitySample Rate: 1 to 100 samples per second, selectableAuto Zero Range: 0.5 or 1 through 9 divisionsWeighing Units: Pounds, Ounces, Kilograms, GramsKeypad: Color Coded Capacitive Touch type, 7 keysStandard I/O: (1) bi-directional RS232