Model 190 Installation, Technical and Operation8400-M022-O1 Rev J Page 1219.2 Error CodesThe Cardinal 190 Weight Indicator is equipped with software that indicateswhen an error in the operation takes place. The following lists the errorcodes displayed by the 190 along with their meaning. Should youencounter an error code, please refer to this list for the cause.Error Cause (A.) and Corrective Action (B.)ConFig A. Calibration required.B. Calibrate the scale with test weights.ErrA h A. The analog input is off scale at the upper end of theinput range.B. Check wiring and load cell.ErrA L A. The analog input is off scale at the lower end of theinput range.B. Check wiring and load cell.Error A. Attempt to perform an illegal function:1. Performing a hold operation when the weight isinvalid (e.g., overcapacity).2. Attempting to clear Tare with Gross weight greaterthan zero (lft=1, usa=0).3. Attempting to zero scale when there is motionpresent or the scale is over capacity.4. Attempting to zero scale when Gross weight is outof zero range (trL=yES).5. Attempting to print when scale is over capacity.6. Attempting to do a span adjustment withinsufficient load on the scale.7. Attempting to tare scale when there is motionpresent or the Gross weight is below zero or overcapacity.Lo bAt A. This message is used with the battery operation andwill turn ON to indicate the battery does not have asufficient charge and requires recharging.If continued use furthers drains the battery, no changein operation will occur until just before the batteryvoltage drops to a level where operation is affected.At this level, the indicator will automatically turn off.B. Charge the battery pack or replace it.