Table 82: Configuration parameters limits error (0x6383 / 0x164)Code PROFINET®codeName Severity (warn‐ing/error/triplock)Description LCP name0x6383 0x164 Configuration pa-rameters limits er-rorTrip lock ≥1 parameter in the configuration parameterset is out of limits: the parameter set is notvalid for this device.conf parlim9.3.48 Power EEprom configuration error (0x6384 / 0x166)This error is valid for PSM 510, DAM 510, ACM 510, and SDM 511/SDM 512.Table 83: Power EEprom configuration error (0x6384 / 0x166)Code Name Severity (warning/error/trip lock)Description LCP name0x6384 0x166 Power Eeprom config-uration errorTrip lock The power device Eeprom is corrupt orincompatible with this control board.conf par EE-PROM9.3.49 Brake chopper failure (0x7111 / 0x141)This error is valid for PSM 510.Table 84: Brake chopper failure (0x7111 / 0x141)Code PROFINET®codeName Severity (warning/error/trip lock)Description LCP name0x7111 0x141 Brake chop-per failureWarning, error The brake chopper is monitored during oper-ation.A brake failure has been detected by thebrake check function.brake ch fail9.3.50 Brake chopper overcurrent (0x7112 / 0x167)This error is valid for PSM 510.Table 85: Brake chopper overcurrent (0x7112 / 0x167)Code PROFINET®codeName Severity (warning/error/trip lock)Description LCP name0x7112 0x167 Brake chopperovercurrentTrip lock The brake chopper current ex-ceeds the limit.brake ch over-curr9.3.51 Brake resistor maximum power limit (0x7181 / 0x142)This error is valid for PSM 510.DiagnosticsOperating Guide | VLT® Multiaxis Servo Drive MSD 510 SystemAQ262450196490en-000101 / 175R1170| 183Danfoss A/S © 2019.10