3 - 329Chapter 3 Removal and Replacement Procedures (RRPs)RRP14.17 HARNESS-ASSY FEED 2 (PL 14.3.13)[Removal]1) Remove 500 SHEET FEEDER ASSEMBLY. (RRP 14.5)2) Remove 500 SHEET FEEDER LEFT COVER. (RRP 14.6)3) Release the two clamps that fixes the harness of HARNESS-ASSY FEED 2 (PL 14.3.13).4) Remove the connector (P/J436) on PWBA TRAY CONT (PL 14.3.12).5) Release the hooks at two locations that fix HARNESS-ASSY FEED 2 to 500 SHEET FEEDERASSEMBLY, and remove HARNESS-ASSY FEED 2.[Replacement]1) Attach HARNESS-ASSY FEED 2 on 500 SHEET FEEDER ASSEMBLY and fix it with twohooks.2) Attach the connector (P/J436) on PWBA-TRAY CONT.3) Fix the harness of HARNESS-ASSY FEED 2 using the two clamps.4) Attach 500 SHEET FEEDER LEFT COVER. (RRP 14.6)5) Attach 500 SHEET FEEDER ASSEMBLY. (RRP 14.5)