1 - 272Chapter 1 TroubleshootingVersion 1 2008.02.15FIP1.72 Over Heat 042-700/Ready to Print 142-700Step Check Yes NoPossible causative parts:KIT FEEDER ASSY (PL3.2.99)PWBA MCU (PL9.1.20)1 Checking the room temperatureIs the room temp. Over 32 degrees C?Change the roomor cool down theroomGo to step 2.2 Checking the printingDid the client print the large volume of printing? Go to step 3. Go to step 4.3 Checking the printing after cool down of five minutes.Does the error still occur when printing? Go to step 4. End of work4Checking the PWBA MCUReseat the PWBA MCU.Does the error still occur when printing?Go to step 5. End of work5Checking after replacing the PWBA MCUReplace the PWBADoes the error still occur when printing?Replace the KITFEEDER ASSY.(Refer to Removal40/Replacement4)End of work