8 – 9Chapter 8 Printer SpecificationsVersion 1 2007.12.284.7 Warm-up TimeWhen nominal voltage (100V, 115V, 220V) is applied, the printer will proceed to standby mode fromPOWER-ON within 30 seconds.Reference: Measured at 22°C, 55% RH, nominal voltage.4.8 FPOT (First Print Output Time)FPOT time of the printer is shown in the table below.The time required for the first sheet of paper to be delivered after the PRINT indication is given iscalculated on the following conditions (rounded to one decimal place).• IOT performance that the controller does not have IOT wait.• The printer is in the standby mode. (ROS MOTOR OFF, FUSER READY)• Paper is A4 SEF• Except when process control is operating*1*1:Process controller operation is process controls such as TC control, electric potential control,cleaning cycle, registration control, and so on. Sometimes, the engine stops feeding papers fora certain period of time while continuous printing for these operations.Color Mode Paper Tray FPOT (Sec.)B/WMPF 16 sec. or lessStandard tray 16 sec. or lessOptional 2nd tray 16.5 sec. or lessColorMPF 17 sec. or lessStandard tray 17 sec. or lessOptional 2nd tray 17.5 sec. or less