Stacking | 993Manage Redundancy on an S-Series StackReset a Unit on an S-Series StackYou may reset any stack unit except for the master management unit (Message 2).Verifying a Stack ConfigurationLED Status Indicators on an S4810 StackThe light of the LED status indicator on the front panel identifies the unit’s role in the stack.• Off indicates the unit is a stack member.• Blinking Green indicates the unit is the stack standby.• Solid Green indicates the unit is the stack master (management unit)Task Command Syntax Command ModeReset the current management unit, and makethe standby unit the new master unit. A newstandby is elected. When the former stackmaster comes back online, it becomes amember unit.redundancy force-failover stack-unit EXEC PrivilegePrevent the stack master from rebooting after afailover. This command does not affect aforced failover, manual reset, or a stack-linkdisconnect.redundancy disable-auto-reboot stack-unit CONFIGURATIONDisplay redundancy information. show redundancy EXEC PrivilegeMessage 2 Master Reset Disallowed% Error: Reset of master unit is not allowed.Task Command Syntax Command ModeReload a stack-unit reset stack-unit EXEC PrivilegeReload a member unit, from the unit itself reset-self EXEC PrivilegeReset a stack-unit when the unit is in a problem state. reset stack-unit {hard} EXEC Privilege