3-2 Dell PowerEdge 4200 Systems Installation and Troubleshooting GuideTable 3-1. System MessagesMessage Cause Action512 MByte mem-ory limitexceeded - Mem-ory above 512MBytes disabled.The system supports amaximum of 512 MB ofmemory. Excess mem-ory is not used.Remove extra DIMMs. See “Removing DIMMs” in Chapter 8.EISA configura-tion errorThe EISA data inNVRAM does notmatch the installedEISA expansion cards.Verify that any installed EISA expansion cards are properlyseated, and then run the EISA Configuration Utility to verifythat the configuration parameters are correct. See Chapter 5,“Using the EISA Configuration Utility,” in the User’s Guide.EISA configura-tion NVRAM badThe EISA jumper mayhave been accidentallyinstalled.Remove the EISA jumper, reboot the system, and restore theEISA configuration parameters. See Chapter 5, “Using theEISA Configuration Utility,” in the User’s Guide.Embedded servermanagement errorThe embedded servermanagement memorymay be temporarilycorrupted.Turn off the system to clear the memory, and then restart thesystem.Embedded servermanagement firm-ware downloadfailedThe embedded servermanagement memorymay be temporarilycorrupted.Turn off the system to clear the memory, and then restart thesystem.Incorrect driveA type - RunSetupIncorrect driveB type - RunSetupThe installed diskettedrive type does notmatch the diskette drivetype in CMOS.Run the System Setup program to correct the diskette drivetype.Invalid CPUspeed detected -check jumpersThe microprocessor-speed jumper plug maybe absent or installed onthe wrong pins.Check the microprocessor speed jumpers. See Table C-1.Invalid CPU speeddetected - Checkspeed jumpers.System halted.The microprocessorspeed detected is notvalid.Check the microprocessor speed jumpers. See Table C-1.NOTE: For the full name of an abbreviation or acronym used in this table, see the abbreviation and acronym list.