MGR10 A/B/C - Revision : I (for 7.0 software revision) 756.3.4 Other function CommandsTemperature Compensation GroupSENSe:TCOMpensate:STATe or <1|0>Enables or disables the temperature compensation facility.Temperature compensation is not available in FAST mode. Attempting to set the state “ON” willgenerate an “execution error”.SENSe:TCOMpensate:STATe?Returns “0” (OFF) or “1” (ON).SENSe:TCOMpensate:MODE or manual temperature>Sets the temperature compensation facility to either external Pt100 probe measurement, or to afixed temperature, which is entered in the current temperature unit (ºC or ºF). Range is 0 - 100 ºC(32 - 212°F).SENSe:TCOMpensate:MODE?Returns “EXT”, or “MAN”,<manual temperature>.SENSe:TCOMpensate:COEFficient or user coefficient>Sets the temperature coefficient to Copper, Aluminium or to a user-defined value, which is enteredin ppm/ºC (0 - 9999).SENSe:TCOMpensate:COEFficient?Returns “CU”,, or “AL”,, or“USER”,. The coefficients are quoted in ppm/ºC.UNIT:TEMPerature: Sets the temperature unit to ºCelsius or ºFarenheit.UNIT:TEMPerature?Returns “CEL” or “FAR”.SENSe:TCOMpensate:REFerence <temperature value>Sets the reference temperature. This is the temperature to which resistance measurements arecompensated (normally 20ºC). It is entered in the current temperature unit (ºC or ºF). Range is 0 -50ºC (32 - 122°F), in integer values of ºC, or the ºF equivalent.SENSe:TCOMpensate:REFerence?Returns the reference temperature in the current temperature unit.