5User Manual MN040024ENEffective November 2016DX-NET-ETHERNET2-2 field bus connectionEtherNet/IP for variable frequency drive DE1/DC1EATON www.eaton.comEngineeringEtherNet/IPEtherNet/IP (Ethernet Industrial Protocol) is an open industrialstandard that is based on the standards for “normal” Ethernet(IEEE 802.3) and that expands on them with an industrial protocol.EtherNet/IP can be used to connect devices from different vendorsto each other, as well as to have these devices communicate witheach other.The EtherNet/IP protocol supports communications between variouscontrol products, enabling devices to transfer time-critical applicationdata between each other in an industrial environment. The spectrumof supported devices ranges from simple I/O devices (e.g., sensors)to complex controllers.EtherNet/IP supports the TCP/IP protocol family and expands it forcontroller applications with the Common Industrial Protocol (CIP).CIP is used as a real-time application protocol for inputs/outputs.The number of cards on an EtherNet/IP system is virtually unlimited.LED indicatorsThe module’s LED indicators are used to indicate operating andnetwork statuses, making quick diagnostics possible.Figure 4. LED indicatorsNS (Network status)The network status LED (NS) is used to indicate network statuses.Table 1. Network status indicatorState IndicatorSteady Off Not powered, no IP addressSteady Green Online, one or more connections activeFlashing Green Online, no connections activeFlashing Red Connection timeoutSteady Red Duplicate IPFlashing Green and Red Self-testMS (Module Status)The module status LED (MS) is used to indicate the EtherNet/IPmodule’s status.Table 2. Module status indicatorState IndicatorSteady Off No powerSteady Green Operating in normal conditionFlashing Green Drive not configuredFlashing Red Minor fault - Recoverable faultSteady Red Major fault - Unrecoverable faultFlashing Green / Red Self-testLINK/Activity LEDThe LINK/Activity LED is used to indicate communications statuses.Table 3. Link activity LEDs (P1/P2)Link activityLEDs (P1/P2) State IndicatorP1 Speed Steady Yellow 100 Mbps link activeSteady Off 10 Mbps or No linkP1 Link Activity Steady Green Valid LinkSteady Off No LinkFlash TX/RXP2 Speed Steady Yellow 100 Mbps link activeSteady Off 10 Mbps or No linkP2 Link Activity Steady Green Valid LinkSteady Off No LinkFlash TX/RXCOMMThe comm status LED is used to indicate the status of the ModbusCommunication between the drive and module.Table 4. COMMState IndicatorSteady Off Modbus protocol TX/RX inactiveSteady/flashing Yellow Modbus protocol TX/RX activeErrorThe Error status LED is used to indicate the status of the ModbusCommunication between the drive and module.Table 5. ERRORState IndicatorSteady Off Modbus protocol TX/RX inactiveSteady Red Non-recoverable internal fault – Modbuscommunications circuit faultFlashing Red Recoverable Communication fault or configuration errorPower up sequenceAt power up, the following LED test sequence is performed inparallel:• Network Status Indicator – 0.25 sec RED, 0.25 sec Green• Module Status Indicator – 0.25 sec RED, 0.25 sec Green• COMM – 0.5 sec Yellow, 0.5 sec Off• ERROR – 0.5 sec Off, 0.5 sec RED