Settings Options and Partitions MenusPage 53PZ Set ResponseSpecifies the system response for activations of zones of type Perimeter in the set state.In a partitioned system, each partition can have different response. In a part-settingsystem, this option applies to the complete system.Note: For a part-setting system, this option appears in System Options.SilentActivation inserted into non-mandatory log.No internal sounders.Outputs of type Perimeter and Perimeter Timer activate.Outputs of type Perimeter Timer deactivate on expiry of PZ Reset Time (see below)or code entry.InternalActivation inserted into non-mandatory log.Internal sounders activate.Outputs of type Perimeter and Perimeter Timer activate.Internal sounders silenced by user code, etc.Outputs of type Perimeter Timer deactivate on expiry of PZ Reset Time (see below)or code entry.SirenActivation inserted into non-mandatory log.Internal and external sounders activate.Outputs of type Perimeter and Perimeter Timer activate.Internal and external sounders silenced by user code, etc.Outputs of type Perimeter Timer deactivate on expiry of PZ Reset Time (see below)or code entry.FullActivation inserted into non-mandatory log.Internal and external sounders activate.Outputs of type Perimeter and Perimeter Timer activate.Communications active.Internal and external sounders silenced by user code, etc.Outputs of type Perimeter Timer deactivate on expiry of PZ Reset Time (see below)or code entry.Communications restored by user code entry.PZ Reset TimeThis determines the maximum period of time that outputs of type Perimeter Timer will beactive.In a partitioned system, each partition can have different reset time. In a part-settingsystem, this option applies to the complete system.The reset time can be set from 0-999 seconds. Setting the time to 0 requires a user toenter a code to deactivate outputs of type Perimeter.Note: For a part-setting system, this option appears in System Options.