Lumina 35 House setup31HOUSE SETUP → tab page UserApply temperature curve Setting indicating if the house temperature is to be controlled based on the curve.Apply ventilation curve Setting indicating if the minimum and maximum ventilation levels are to be controlledbased on the curve.Data linked to animals Setting indicating that clocks are only to be controlled if there are animals in the house.The control computer will also calculate the feed and water amounts based on thenumber of set up animals.Ventilation standard Setting used to determine how the minimum ventilation standard is entered:• As a percentage, irrespective of the number of animals.• Per animal (m3/h/animal).• Per kilo animal weight (m3/h/kg).Time-link light Setting indicating if clocks are to be linked to other clocks.Fancom HumiTemp Setting indicating if HumiTemp is to be used to correct the house temperature.Apply light scheme Setting indicating if the user uses light schemes.Apply OptiSec Setting indicating if OptiSec is to be used to influence the control value heating and starttemperature ventilation.See also: OptiSec-settings page 41.