Lumina 35 Installer48Measurement outsideRHSetting if the control computer carries out outside measurement concerned itself (INT)or via the communication network (COMM). Only enter the address of the input if INT isselected.Address Setting the address of the analog input.INSTALLER → OUTSIDE CLIMATE → tab page WindMeasurement wind Setting if the control computer carries out outside measurement concerned itself (INT)or via the communication network (COMM). Only enter the address of the input if INT isselected.Input wind speed Setting of the address of the digital input.Type wind measure Setting of the type of anemometer used. Fancom uses the following types of weathermeters:• GREEN_2P (default)• BLACK_4P• BLACK_2P• DAVIS• PA2By choosing the required type and assigning the correct inputs, the control computer willautomatically make all corresponding settings.Input wind vane Setting the address of the analog input.Wind direction Readout of the current wind direction.Wind relay address Setting of the address of the digital input.