Lumina 35 Installer47Address Setting of the address of the digital input.Registration input Setting the type of measurement:• MANUALLY: Enables you to enter the amount of today manually.• SLOW PULSE: Measuring instruments with a maximum frequency of 20 pulses persecond (20 Hz).• QUICK PULSE: Measuring instruments with a maximum frequency of 20 pulses persecond (20 Hz) (only use when there is a link with a switch clock).• CONTACT: As long as the sensor makes contact, the value will be added upcumulatively. The amount is therefore determined by time the contact is HIGH.Unit per pulse Setting of the unit that corresponds to one pulse. (only with measurement type: SLOWPULSE or QUICK PULSE)Unit per minute* Setting of the number of 'units' measured per minute. This option is only available ifDisplay=AMOUNT. (only with measurement type: CONTACT)Display* Setting how the unit is displayed:• AMOUNT: number 'units' per minute (Amount per min.).• TIME: the time the contact makes contact. (only with measurement type:CONTACT).Unit today* Readout of the unit measured today. Reset this value to start all registration from zeroagain.Input status* Readout of the actual input status. HIGH or LOW. (only with measurement type:CONTACT).Total Readout of the total unit measurements.The control computer can carry out various outside measurements. These measurements can also be done byanother control computer in the network.INSTALLER → OUTSIDE CLIMATE → tab page Temp/RHMeasurement outsidetemp.Setting if the control computer carries out outside measurement concerned itself (INT)or via the communication network (COMM). Only enter the address of the input if INT isselected.Address Setting the address of the analog input.