GE Multilin F60 Feeder Protection System B-29APPENDIX B B.4 MEMORY MAPPINGB411C IEC Communications Reserved (33 items) 0 to 1 --- 1 F001 0413E High Enet Traffic Function 0 to 1 --- 1 F102 0 (Disabled)413F High Enet Traffic Events 0 to 1 --- 1 F102 0 (Disabled)4140 DNP object 1 default variation 1 to 2 --- 1 F001 24141 DNP object 2 default variation 1 to 3 --- 1 F001 24142 DNP object 20 default variation 0 to 3 --- 1 F523 0 (1)4143 DNP object 21 default variation 0 to 3 --- 1 F524 0 (1)4144 DNP object 22 default variation 0 to 3 --- 1 F523 0 (1)4145 DNP object 23 default variation 0 to 3 --- 1 F523 0 (1)4146 DNP object 30 default variation 1 to 5 --- 1 F001 14147 DNP object 32 default variation 0 to 5 --- 1 F525 0 (1)Communications Actuals (Read Only)4160 Modbus Available TCP/IP Connections 0 to 4 --- 1 F001 44161 DNP Available TCP/IP Connections 0 to 2 --- 1 F001 24162 IEC Available TCP/IP Connections 0 to 2 --- 1 F001 24163 MMS Available TCP/IP Connections 0 to 5 --- 1 F001 54164 PMU Available TCP/IP Connections 0 to 4 --- 1 F001 4Simple Network Time Protocol (Read/Write Setting)4168 Simple Network Time Protocol (SNTP) function 0 to 1 --- 1 F102 0 (Disabled)4169 Simple Network Time Protocol (SNTP) server IP address 0 to 4294967295 --- 1 F003 0416B Simple Network Time Protocol (SNTP) UDP port number 1 to 65535 --- 1 F001 123Data Logger Commands (Read/Write Command)4170 Data Logger Clear 0 to 1 --- 1 F126 0 (No)Data Logger (Read/Write Setting)4181 Data Logger Channel Settings (16 items) --- --- --- F600 04191 Data Logger Mode 0 to 1 --- 1 F260 0 (continuous)4192 Data Logger Trigger 0 to 4294967295 --- 1 F300 04194 Data Logger Rate 15 to 3600000 ms 1 F003 60000Clock (Read/Write Setting)419F Synchronizing Source 0 to 3 --- 1 F623 0 (none)Clock (Read/Write Command)41A0 Real Time Clock Set Time 0 to 235959 --- 1 F050 0Clock (Read/Write Setting)41A2 SR Date Format 0 to 4294967295 --- 1 F051 041A4 SR Time Format 0 to 4294967295 --- 1 F052 041A6 IRIG-B Signal Type 0 to 2 --- 1 F114 0 (None)41A7 Clock Events Enable / Disable 0 to 1 --- 1 F102 0 (Disabled)41A8 Time Zone Offset from UTC –24 to 24 hours 0.5 F002 041A9 Daylight Savings Time (DST) Function 0 to 1 --- 1 F102 0 (Disabled)41AA Daylight Savings Time (DST) Start Month 0 to 11 --- 1 F237 0 (January)41AB Daylight Savings Time (DST) Start Day 0 to 6 --- 1 F238 0 (Sunday)41AC Daylight Savings Time (DST) Start Day Instance 0 to 4 --- 1 F239 0 (First)41AD Daylight Savings Time (DST) Start Hour 0 to 23 --- 1 F001 241AE Daylight Savings Time (DST) Stop Month 0 to 11 --- 1 F237 0 (January)41AF Daylight Savings Time (DST) Stop Day 0 to 6 --- 1 F238 0 (Sunday)41B0 Daylight Savings Time (DST) Stop Day Instance 0 to 4 --- 1 F239 0 (First)41B1 Daylight Savings Time (DST) Stop Hour 0 to 23 --- 1 F001 2Fault Report Commands (Read/Write Command)41B2 Fault Reports Clear Data Command 0 to 1 --- 1 F126 0 (No)Oscillography (Read/Write Setting)41C0 Oscillography Number of Records 3 to 64 --- 1 F001 1541C1 Oscillography Trigger Mode 0 to 1 --- 1 F118 0 (Auto.Overwrite)41C2 Oscillography Trigger Position 0 to 100 % 1 F001 50Table B–9: MODBUS MEMORY MAP (Sheet 21 of 68)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT