B-32 F60 Feeder Protection System GE MultilinB.4 MEMORY MAPPING APPENDIX BB4510 ...Repeated for VT Bank 34518 ...Repeated for VT Bank 44520 ...Repeated for VT Bank 54528 ...Repeated for VT Bank 6Source Settings (Read/Write Setting) (6 modules)4580 Source 1 Name 0 to 1 --- --- F206 “SRC 1"4583 Source 1 Phase CT 0 to 63 --- 1 F400 04584 Source 1 Ground CT 0 to 63 --- 1 F400 04585 Source 1 Phase VT 0 to 63 --- 1 F400 04586 Source 1 Auxiliary VT 0 to 63 --- 1 F400 04587 ...Repeated for Source 2458E ...Repeated for Source 34595 ...Repeated for Source 4459C ...Repeated for Source 545A3 ...Repeated for Source 6Power System (Read/Write Setting)4600 Nominal Frequency 25 to 60 Hz 1 F001 604601 Phase Rotation 0 to 1 --- 1 F106 0 (ABC)4602 Frequency And Phase Reference 0 to 5 --- 1 F167 0 (SRC 1)4603 Frequency Tracking Function 0 to 1 --- 1 F102 1 (Enabled)Incipient cable fault detector (read/write settings)46B2 Incipient cable fault detector 1 function 0 to 1 --- 1 F102 0 (Disabled)46B3 Incipient cable fault detector 1 block 0 to 4294967295 --- 1 F300 046B5 Incipient cable fault detector 1 source 0 to 5 --- 1 F167 0 (SRC 1)46B6 Incipient cable fault detector 1 pickup 0.1 to 10 pu 0.01 F001 5046B7 Incipient cable fault detector 1 mode 0 to 1 --- 1 F254 0 (Number ofCounts)46B8 Incipient cable fault detector 1 counts 1 to 10 --- 1 F001 246B9 Incipient cable fault detector 1 time window 0 to 1000 s 0.01 F003 100046BB Incipient cable fault detector 1 reset delay 0 to 65.535 s 0.001 F001 10046BC Incipient cable fault detector 1 target 0 to 2 --- 1 F109 0 (Self-reset)46BD Incipient cable fault detector 1 events 0 to 1 --- 1 F102 0 (Disabled)46BE ...Repeated for incipient cable fault detector 2Breaker control (read/write settings)47D0 Breaker 1 function 0 to 1 --- 1 F102 0 (Disabled)47D1 Breaker 1 name --- --- --- F206 “Bkr 1"47D4 Breaker 1 mode 0 to 1 --- 1 F157 0 (3-Pole)47D5 Breaker 1 open 0 to 4294967295 --- 1 F300 047D7 Breaker 1 close 0 to 4294967295 --- 1 F300 047D9 Breaker 1 phase A / three-pole closed 0 to 4294967295 --- 1 F300 047DB Breaker 1 phase B closed 0 to 4294967295 --- 1 F300 047DD Breaker 1 phase C closed 0 to 4294967295 --- 1 F300 047DF Breaker 1 external alarm 0 to 4294967295 --- 1 F300 047E1 Breaker 1 alarm delay 0 to 65.535 s 0.001 F003 047E3 Breaker 1 pushbutton control 0 to 1 --- 1 F102 0 (Disabled)47E4 Breaker 1 manual close recall time 0 to 4294967295 s 0.001 F003 047E6 Breaker 1 out of service 0 to 4294967295 --- 1 F300 047E8 Breaker 1 block open 0 to 4294967295 --- 1 F300 047EA Breaker 1 block close 0 to 4294967295 --- 1 F300 047EC Breaker 1 phase A / three-pole opened 0 to 4294967295 --- 1 F300 047EE Breaker 1 phase B opened 0 to 4294967295 --- 1 F300 047F0 Breaker 1 phase C opened 0 to 4294967295 --- 1 F300 047F2 Breaker 1 operate time 0 to 65.535 s 0.001 F001 7047F3 Breaker 1 events 0 to 1 --- 1 F102 0 (Disabled)Table B–9: MODBUS MEMORY MAP (Sheet 24 of 68)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT