B-70 F60 Feeder Protection System GE MultilinB.4 MEMORY MAPPING APPENDIX BBD290 ...Repeated for Remote Output 29D294 ...Repeated for Remote Output 30D298 ...Repeated for Remote Output 31D29C ...Repeated for Remote Output 32Remote Output UserSt Pairs (Read/Write Setting) (32 modules)D2A0 Remote Output UserSt 1 Operand 0 to 4294967295 --- 1 F300 0D2A1 Remote Output UserSt 1 Events 0 to 1 --- 1 F102 0 (Disabled)D2A2 Reserved (2 items) 0 to 1 --- 1 F001 0D2A4 ...Repeated for Remote Output 2D2A8 ...Repeated for Remote Output 3D2AC ...Repeated for Remote Output 4D2B0 ...Repeated for Remote Output 5D2B4 ...Repeated for Remote Output 6D2B8 ...Repeated for Remote Output 7D2BC ...Repeated for Remote Output 8D2C0 ...Repeated for Remote Output 9D2C4 ...Repeated for Remote Output 10D2C8 ...Repeated for Remote Output 11D2CC ...Repeated for Remote Output 12D2D0 ...Repeated for Remote Output 13D2D4 ...Repeated for Remote Output 14D2D8 ...Repeated for Remote Output 15D2DC ...Repeated for Remote Output 16D2E0 ...Repeated for Remote Output 17D2E4 ...Repeated for Remote Output 18D2E8 ...Repeated for Remote Output 19D2EC ...Repeated for Remote Output 20D2F0 ...Repeated for Remote Output 21D2F4 ...Repeated for Remote Output 22D2F8 ...Repeated for Remote Output 23D2FC ...Repeated for Remote Output 24D300 ...Repeated for Remote Output 25D304 ...Repeated for Remote Output 26D308 ...Repeated for Remote Output 27D30C ...Repeated for Remote Output 28D310 ...Repeated for Remote Output 29D314 ...Repeated for Remote Output 30D318 ...Repeated for Remote Output 31D31C ...Repeated for Remote Output 32IEC 61850 GGIO2 Control Configuration (Read/Write Setting) (64 modules)D320 IEC 61850 GGIO2.CF.SPCSO1.ctlModel Value 0 to 2 --- 1 F001 2D321 IEC 61850 GGIO2.CF.SPCSO2.ctlModel Value 0 to 2 --- 1 F001 2D322 IEC 61850 GGIO2.CF.SPCSO3.ctlModel Value 0 to 2 --- 1 F001 2D323 IEC 61850 GGIO2.CF.SPCSO4.ctlModel Value 0 to 2 --- 1 F001 2D324 IEC 61850 GGIO2.CF.SPCSO5.ctlModel Value 0 to 2 --- 1 F001 2D325 IEC 61850 GGIO2.CF.SPCSO6.ctlModel Value 0 to 2 --- 1 F001 2D326 IEC 61850 GGIO2.CF.SPCSO7.ctlModel Value 0 to 2 --- 1 F001 2D327 IEC 61850 GGIO2.CF.SPCSO8.ctlModel Value 0 to 2 --- 1 F001 2D328 IEC 61850 GGIO2.CF.SPCSO9.ctlModel Value 0 to 2 --- 1 F001 2D329 IEC 61850 GGIO2.CF.SPCSO10.ctlModel Value 0 to 2 --- 1 F001 2D32A IEC 61850 GGIO2.CF.SPCSO11.ctlModel Value 0 to 2 --- 1 F001 2D32B IEC 61850 GGIO2.CF.SPCSO12.ctlModel Value 0 to 2 --- 1 F001 2D32C IEC 61850 GGIO2.CF.SPCSO13.ctlModel Value 0 to 2 --- 1 F001 2D32D IEC 61850 GGIO2.CF.SPCSO14.ctlModel Value 0 to 2 --- 1 F001 2Table B–9: MODBUS MEMORY MAP (Sheet 62 of 68)ADDR REGISTER NAME RANGE UNITS STEP FORMAT DEFAULT