Service Manual September 2016Checklist B Procedures48 AWP Super Series • IWP Super Series Part No. 38139B-3 Ins pect All W eldsB-3Inspect All WeldsGenie specifications require that this procedure beperformed every 250 hours or quarterly, whichevercomes first.Weld inspections are essential to safe machineoperation and good machine performance. Failureto locate and repair damage may result in anunsafe operating condition.1 Visually inspect the welds in the followinglocations:• Platform• Base• Mast brace mounting bracketAWPS models:• Loading pivot bar• Outrigger storage sockets• Tilt-back frame (if equipped)• Tilt-back frame mounting bracket (ifequipped)IWPS models:• Foot pads• Power wheel assist (if equipped)B-4 T est the Tilt-back Oper ation (if equipped)B-4Test the Tilt-back Operation (ifequipped)Genie specifications require that this procedure beperformed every 250 hours or quarterly, whichevercomes first.A tilt-back frame is standard equipment onAWP-36S and 40S and optional on AWP-15S, 20S,25S and 30S. The tilt-back rame allows themachine to be rolled through a standard doorway.Failure to detect improper tilt-back operation couldresult in unsafe operating conditions and maycause injury and component damage.1 Fully lower the platform to the stowed position.2 Remove the outriggers from the base andplace in the storage sockets.3 Maintain a firm grasp on the tilt-back frameand remove the retaining pin.4 Lower the tilt-back frame and guide thetilt-back strut into the strut socket.