Service Manual September 2016Checklist B Procedures56 AWP Super Series • IWP Super Series Part No. 381397 Repeat steps 4 and 5 using a ½ inch / 12.7mm spacer.8 Pull the base lowering handle to fully lower thebase.Result: Within 1 to 4 seconds, two interlockdisplay lights should turn off and remain off.9 Repeat steps 4 through 8 to test the oppositeside of the machine.10 Pump the foot pedal to raise the base.11 Place a ¾ inch / 19 mm thick spacer underboth adjustable foot pads.12 Pull the base lowering handle to fully lower thebase.Result: Within 1 to 4 seconds, all four interlockdisplay lights should turn on and remain on.13 Pump the foot pedal to raise the base.14 Turn the leveling jacks counterclockwiseenough to fit a 1½ inch / 3.8 cm spacer undereach adjustable foot pad.15 Turn the leveling jacks clockwise until the footpads just touch the spacers.16 Pull the base lowering handle to fully lower thebase.Result: Within 1 to 4 seconds, two interlockdisplay lights should turn off and remain off.17 Pump the foot pedal to raise the base.18 To test the non-adjustable foot pads, turn theleveling jacks counterclockwise all the way.19 Place a 1½ inch / 3.8 cm spacer under eachnon-adjustable foot pad.20 Pull the base lowering handle to fully lower thebase.Result: Within 1 to 4 seconds, two interlockdisplay lights should turn off and remain off.B-12 C hec k the Chai nAdj ustm ent, IW P-20S Models with Outreach Opti onB-12Check the Chain Adjustment,IWP-20S Models with OutreachOptionGenie requires that this procedure be performedevery 250 hours or quarterly, whichever comesfirst.Detection of a improperly adjusted platformoutreach chain is essential for safe machineoperation. Failure to detect an improperly adjustedplatform outreach chain could result in unsafeoperating conditions and may cause injury andcomponent damage.1 Fully lower the platform.2 Lower the base and turn the key switch off.3 Fully extend the outreach and lock the handle.4 Locate the chain between the lower sprocketand the lower brace.5 Grasp the two chain sections and lightly pinchthem together.Result: There should be a minimum of a ¼inch / 6.4 mm gap between the chain sections.Note: If measurement does not meet specification,adjust the chains. Refer to Repair Procedure, Howto Adjust the Platform Outreach Chain.