September 2016 Service ManualBase AssemblyPart No. 38139 AWP Super Series • IWP Super Series 65Base A ssembly1-1 Interl ocks1-1InterlocksAWPS models: The interlock contacts indicateproper installation of the outriggers and only allowthe machine to operate when the outriggers areproperly installed and adjusted.IWPS models: The base interlock switchesindicate that the foot pads are in firm contact withthe ground.How to Remove an InterlockContact - AWP Models1 Fully lower the platform.2 Turn the key switch off and remove the key.3 Store the outriggers in the storage sockets.4 Remove the rear base cover.1 base2 terminal switch5 Trace the interlock contact wires to the rear ofthe base.6 Locate the terminal strip.7 Label and remove the contact wires byinserting a small screwdriver into the holebelow the wire and gently push in while pullingon the wire.8 Follow the wires to the grommets where thewire enters and exits the base. Pull the wiresthrough the grommets and the base.Note: Only pull the wires out far enough to accessthe interlock contact bracket mounting fasteners.9 Remove the interlock contact bracketmounting fasteners from the outrigger basesocket.How to Remove a Base InterlockSwitch - IWPS Models1 Fully lower the platform.2 Turn the key switch off and remove the key.3 Pull the base lowering handle to fully lower thebase.4 Remove the foot pad switch bracket fasteners.5 Pull the foot pad switch bracket out of thebase.1 switch bracket cover2 switch bracket fasteners6 Remove the wires from the switch. Note thewire positions.7 Remove the fastener that attaches the switchto the switch bracket.