Error Code/Symptom FRU/Action1600 (The Service Processor is notfunctioning) Do the following beforereplacing a FRU:1. Ensure that a jumper is not installedon J45.2. Remove the ac power to the system,wait 20 seconds; then, re-connect theac power. Wait 30 seconds; then,power-on the system.1. System Board1601 (The system is able to communicateto the Service Processor, but the ServiceProcessor failed to respond at the start ofPOST.) Do the following before replacinga FRU:1. Remove the ac power to the system,wait 20 seconds; then, re-connect theac power. Wait 30 seconds; then,power-on the system.2. Flash update the Service Processor.1. System Board1762 (Fixed Disk Configuration error) 1. Fixed Disk Drive2. Fixed Disk Cables3. Run Configuration/Setup4. Fixed Disk Adapter5. SCSI Backplane6. System Board178X (Fixed Disk error) 1. Fixed Disk Cables2. Run Diagnostics3. Fixed Disk Adapter4. Fixed Disk Drive5. System Board1800 (No more hardware interruptavailable for PCI adapter) 1. Run Configuration/Setup2. Failing Adapter3. System Board1962 (Drive does not contain a valid bootsector) 1. Verify a bootable operating system is installed.2. Run Diagnostics3. Hard Disk Drive4. SCSI Backplane5. Cable6. System Board2400 (Video controller test failure) 1. Video Adapter (if installed)2. System Board2462 (Video memory configuration error) 1. Video Adapter (if installed)2. System Board94 Hardware Maintenance Manual: xSeries 342 Model 1RX, 2RX, 1TG, 2TG