Error Code/Symptom FRU/Action015-XXX-198 (USB device connected duringUSB test) 1. Remove USB devices from USB1 and USB2.2. Re-run USB external loopback test.3. System Board020-XXX-000 (Failed PCI Interface test) 1. System Board020-XXX-001 (Failed Hot-Swap Slot 1 PCILatch test) 1. PCI Hot-Swap Latch Assembly2. System Board020-XXX-002 (Failed Hot-Swap Slot 2 PCILatch test) 1. PCI Hot-Swap Latch Assembly2. System Board020-XXX-003 (Failed Hot-Swap Slot 3 PCILatch test) 1. PCI Hot-Swap Latch Assembly2. System Board020-XXX-004 (Failed Hot-Swap Slot 4 PCILatch test) 1. PCI Hot-Swap Latch Assembly2. System Board030-XXX-000 (Failed Internal SCSI interfacetest) 1. System Board035-XXX-099 1. No adapters were found.2. If adapter is installed re-check connection.035-XXX-S99 (Failed RAID test on PCI slotS, check System Error Log before replacinga FRU)1. Adapter2. SCSI Backplane3. Cable035-XXX-SNN (Check System Error Logbefore replacing a FRU, NN = SCSI ID offailing fixed disk)1. Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.035-253-S99 (RAID adapter initializationfailure) 1. ServeRAID Adapter in slot S is not configured properly. Obtainthe basic and extended configuration status and refer to theServeRAID Hardware Maintenance Manual for more information.2. Cable3. SCSI Backplane4. Adapter075-XXX-000 (Failed Power Supply test) 1. Power Supply089-XXX-001 (Failed Microprocessor test) 1. VRM 1 for Microprocessor 12. Microprocessor 1089-XXX-002 (Failed OptionalMicroprocessor test) 1. VRM 2 for Optional Microprocessor 22. Optional Microprocessor 2166-250-000 System Management: Failed(I2C cable is disconnected. Reconnect I2Ccable between Remote Supervisor Adapterand System Board.)1. Reseat I2C cables between Remote Supervisor Adapter ( in PCI slot1/J44) and planar (J45)2. I2C Cable(s)86 Hardware Maintenance Manual: xSeries 342 Model 1RX, 2RX, 1TG, 2TG