Repeater lockoutThis function helps prevent interference to other stations byinhibiting your transmission when a signal is received. Thetransceiver has two inhibiting conditions, repeater and busy.q Push [PWR] to turn power OFF.w While pushing [SET(LOCK)], turn power ON to enter initialset mode.e Push [SET(LOCK)] several times until the “RLO” displayappears as shown below.r Rotate the tuning dial to turn the repeater lockout functionto “RP,” “BU” or OFF.• “RP”: Transmit is inhibited when the tone squelch is closed.• “BU”: Transmit is inhibited when a signal is received.t Push [PWR] to exit initial set mode. Reversed duplex modeWhen the reversed duplex mode is selected, the receive fre-quency shifts. (Transmit frequency shifts in normal duplex mode.)Each receive and transmit frequency is shown in the tablebelow with the following conditions;Input frequency : 145.30 MHzDirection : – (negative)Offset frequency : 0.6 MHzq Push [SET(LOCK] to enter set mode.w Push [SET(LOCK)] several times until the “REV” displayappears as shown below.r Rotate the tuning dial to turn the repeater lockout functionto ON or OFF.t Push [V/MHz(SCAN)] to exit set mode.Reverse duplex mode isturned ON.USING SET MODEAuto repeater function isturned OFF.Auto repeater function is ON,tone encoder is ON.While pushing [SET(LOCK)],turn power ON.USING INITIAL SET MODEReversed OFF ONRx frequency 145.30 MHz 144.70 MHzTx frequency 144.70 MHz 145.30 MHz235 REPEATER OPERATION