Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- General
- Safety
- Limits of operation and use
- Risk from electrocution
- Personnel requirements - Qualifications
- Transport, storage and packaging
- Storage
- Technical data
- Construction and function
- Wear parts list
- Installation and wiring
- Requirements governing the installation site
- Minimum clearances
- Installation
- Installation of basic unit
- Installation of casing
- Installing the sheet steel accessories
- Connection to the pipe network
- Sealing the pipework to the valve condensation tray
- Overview of valve kits
- Connection of 2-way valve kit
- Connection of 3-way valve kit
- Connection of differential pressure-dependent valve kit
- Condensation connection
- Electrical wiring
- Electromechanical control, Venkon AC
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916, with condensation monitor
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917, with con
- Electromechanical control, Venkon EC
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942, with condens
- KaControl (*C1)
- Connection (*C1)
- Cabling, Venkon EC, KaControl (*C1*), control by KaController
- Cabling, Venkon EC, KaControl (*C1*), control by in situ 0-10 V DC signal
- Pre-commissioning checks
- Operation
- Operation of the KaController
- Maintenance
- Maintenance work
- Cleaning the main condensation tray
- Cleaning the valve condensation tray
- Clean the inside of the unit
- Faults
- KaControl faults
- List of KaControl parameters
- KaController parameter list
- Certificates
- Table
|
VenkonAssembly, installation and operating instructions25Fig. 12: Standard (left) and alternative (right) air outlet directionChanging the air outlet directionTo change the air outlet direction, loosen the 2 screws, turnthe air outlet grille around 180° and reattach it to the basicunit.6.4.3 Installing the sheet steel accessoriesOverview, air-side sheet steel accessories123 4 5678910 11 1213Fig. 13: Diagram of arrangement of sheet steel accessories for ceiling-mounted units1 Hotel air opening with inlet box and filter 8 Outlet box with hotel air opening2 Internal air grille 9 Discharge box with primary air connection and hotel air opening3 90° duct bend 10 Splitter noise attenuator4 Flexible connector 11 Air duct5 Inlet box with primary air connection 12 Flexible pipe connection unit Ø 198 mm6 Service hatch with frame 13 Ceiling swirl diffuser7 Outlet box with primary air connectionFigure Description Dimensions [mm]160200Hotel air opening with inlet box and filter61 63 66 67A 620 920 1370 1720B 583 883 1333 1683