Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- General
- Safety
- Limits of operation and use
- Risk from electrocution
- Personnel requirements - Qualifications
- Transport, storage and packaging
- Storage
- Technical data
- Construction and function
- Wear parts list
- Installation and wiring
- Requirements governing the installation site
- Minimum clearances
- Installation
- Installation of basic unit
- Installation of casing
- Installing the sheet steel accessories
- Connection to the pipe network
- Sealing the pipework to the valve condensation tray
- Overview of valve kits
- Connection of 2-way valve kit
- Connection of 3-way valve kit
- Connection of differential pressure-dependent valve kit
- Condensation connection
- Electrical wiring
- Electromechanical control, Venkon AC
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916
- Cabling, Venkon AC (*A00M), control by room thermostat type 148916, with condensation monitor
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917
- Cabling, Venkon AC (*A00M), control by room thermostat type 148915/148918/148917, with con
- Electromechanical control, Venkon EC
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30155, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller 30256, with condensation monitor
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942
- Cabling, Venkon EC (*00M or 01M), control by Climate Controller Type 148941/148942, with condens
- KaControl (*C1)
- Connection (*C1)
- Cabling, Venkon EC, KaControl (*C1*), control by KaController
- Cabling, Venkon EC, KaControl (*C1*), control by in situ 0-10 V DC signal
- Pre-commissioning checks
- Operation
- Operation of the KaController
- Maintenance
- Maintenance work
- Cleaning the main condensation tray
- Cleaning the valve condensation tray
- Clean the inside of the unit
- Faults
- KaControl faults
- List of KaControl parameters
- KaController parameter list
- Certificates
- Table
|
VenkonAssembly, installation and operating instructions82.2 Limits of operation and useLimits of operationMin./max. water temperature °C 40-90Min./max. air intake temperature °C 6-40Min./max. air humidity % 15-75Min. operating pressure bar/kPa -Max. operating pressure bar/kPa 10/1000Min./max. glycol percentage % 25-50Tab. 1: Limits of operationOperating voltage 230 V/ 50/60 HzPower/Current consumption On the type plateTab. 2: Operating voltageWe would refer to VDI-2035 Sheets 1 & 2, DIN EN 14336 and DIN EN 14868 with regard to the properties of the mediumused to protect the equipment. The following values provide further guidance.The water used should be free of contamination, such as suspended substances and reactive substances.Water qualitypH value (at 20 °C) 8-9Conductivity (at 20 °C) μS/cm < 700Oxygen content (O2) mg/l < 0.1Hardness °dH 4-8.5Sulphur ions not measurableSodium ions (Na+) mg/l < 100Iron ions (Fe2+) mg/l < 0.1Manganese ions (Mn2+) mg/l <0.05Ammonia ions (NH4+) mg/l < 0.1Chlorine ions (CI) mg/l < 100CO2 < 50Sulfate ions (SO42-) mg/l < 50Nitrite ions (NO2-) mg/l < 50Nitrate ions (NO3-) mg/l < 50Tab. 3: Water quality